Please use this identifier to cite or link to this item:
http://hdl.handle.net/10071/10309Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Dias Pereira, J. M | - |
| dc.contributor.author | Viegas, V. | - |
| dc.contributor.author | Postolache, O. | - |
| dc.contributor.author | Girão, P. M. | - |
| dc.date.accessioned | 2015-12-03T17:29:19Z | - |
| dc.date.available | 2015-12-03T17:29:19Z | - |
| dc.date.issued | 2013 | - |
| dc.identifier.issn | 0860-8229 | por |
| dc.identifier.uri | https://ciencia.iscte-iul.pt/public/pub/id/15038 | - |
| dc.identifier.uri | http://hdl.handle.net/10071/10309 | - |
| dc.description | WOS:000324026300013 (Nº de Acesso Web of Science) | - |
| dc.description.abstract | This paper presents a low-cost and smart measurement system to acquire and analyze mechanical motion parameters. The measurement system integrates several measuring nodes that include one or more triaxial accelerometers, a temperature sensor, a data acquisition unit and a wireless communication unit. Particular attention was dedicated to measurement system accuracy and compensation of measurement errors caused by power supply voltage variations, by temperature variations and by accelerometers’ misalignments. Mathematical relationships for error compensation were derived and software routines for measurement system configuration, data acquisition, data processing, and self-testing purposes were developed. The paper includes several simulation and experimental results obtained from an assembled prototype based on a crank-piston mechanism. | por |
| dc.language.iso | eng | por |
| dc.publisher | Polish Academy Sciences Committee Metrology and Res Equipment | por |
| dc.rights | openAccess | por |
| dc.subject | Measurement system | por |
| dc.subject | Kinematic variables measurements | por |
| dc.subject | Accelerometers | por |
| dc.subject | Error compensation | por |
| dc.subject | Accuracy | por |
| dc.title | A smart and distributed measurement system to acquire and analyze mechanical motion parameters | por |
| dc.type | article | en_US |
| dc.pagination | 465-478 | por |
| dc.publicationstatus | Publicado | por |
| dc.peerreviewed | Sim | por |
| dc.relation.publisherversion | The definitive version is available at: http://dx.doi.org/10.2478/mms-2013-0040 | por |
| dc.journal | Metrology and Measurement Systems | por |
| dc.distribution | Internacional | por |
| dc.volume | 20 | por |
| dc.number | 3 | por |
| degois.publication.firstPage | 465 | por |
| degois.publication.lastPage | 478 | por |
| degois.publication.issue | 3 | por |
| degois.publication.title | Metrology and Measurement Systems | por |
| dc.date.updated | 2015-12-03T17:26:46Z | - |
| Appears in Collections: | CTI-RI - Artigos em revistas científicas internacionais com arbitragem científica | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| publisher_version_mms_2013_0040.pdf | 566,63 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.