Utilize este identificador para referenciar este registo: http://hdl.handle.net/10071/28934
Registo completo
Campo DCValorIdioma
dc.contributor.authorSantos, K. C.-
dc.contributor.authorFernandes, C. A.-
dc.contributor.authorCosta, J. R.-
dc.date.accessioned2023-07-05T14:27:26Z-
dc.date.available2023-07-05T14:27:26Z-
dc.date.issued2023-
dc.identifier.citationSantos, K. C., Fernandes, C. A., & Costa, J. R. (2023). Validation of a compact microwave imaging system for bone fracture detection. IEEE Access, 11, 63690-63700. https://dx.doi.org/10.1109/ACCESS.2023.3287486-
dc.identifier.issn2169-3536-
dc.identifier.urihttp://hdl.handle.net/10071/28934-
dc.description.abstractThis work presents a systematic evaluation of the effectiveness of an air-operated microwave imaging (MWI) system for detection of arbitrarily oriented thin fractures in superficial bones, like the tibia. This includes the proposal of a new compact, portable setup where a single Vivaldi antenna performs a semi-cylindrical scan of the limb. The antenna is operated in monostatic radar mode, near the skin but without contact, thus ensuring hygiene and patient comfort during the exam. The image is reconstructed using a wave-migration algorithm in the frequency domain combined with an adaptative algorithm based on singular value decomposition to remove the skin artifact, dealing with non-uniform bone profile and tissue cover. The study investigates the system resolution, the robustness of the method to the uncertainty of the permittivity and thickness of the involved tested tissues, as well as the robustness to involuntary patient movement. The experimental validation was performed for the first time on an integral ex-vivo animal leg, with all tissues present, including skin and fur. It confirmed both the effectiveness of the method, and the feasibility of the setup.eng
dc.language.isoeng-
dc.publisherIEEE-
dc.relation206841/2014-0-
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F50008%2F2020/PT-
dc.relationinfo:eu-repo/grantAgreement/FCT/9471 - RIDTI/PTDC%2FEEI-TEL%2F30323%2F2017/PT-
dc.rightsopenAccess-
dc.subjectMicrowave imagingeng
dc.subjectBiomedical imagingeng
dc.subjectImage reconstructioneng
dc.subjectBoneseng
dc.titleValidation of a compact microwave imaging system for bone fracture detectioneng
dc.typearticle-
dc.pagination63690 - 63700-
dc.peerreviewedyes-
dc.volume11-
dc.date.updated2023-07-05T15:26:58Z-
dc.description.versioninfo:eu-repo/semantics/publishedVersion-
dc.identifier.doi10.1109/ACCESS.2023.3287486-
iscte.identifier.cienciahttps://ciencia.iscte-iul.pt/id/ci-pub-96290-
iscte.journalIEEE Access-
Aparece nas coleções:IT-RI - Artigos em revistas científicas internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro TamanhoFormato 
article_96290.pdf2,22 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis Logotipo do Orcid 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.